Which ADA signs require tactile characters and braille?
The deciding question is usually what the sign does: permanent room designation, direction, information or a temporary/changeable message.
Permanent room and space identification
Section 216.2 generally requires interior and exterior signs that identify permanent rooms and spaces to comply with the tactile-character provisions of Section 703.2 and the visual-character provisions of Section 703.5. Raised characters are duplicated in contracted braille under Section 703.3.
Common examples include restroom identification, room and floor numbers or letters, and permanent room names. Exterior signs that are not located at the door to the space they serve are not required to have tactile characters. Doors at exit passageways, exit discharge and exit stairways are identified by tactile signs under Section 216.4.1. A project’s adopted code and sign schedule still control the final scope.
Directional and informational signs
Section 216.3 directs signs that provide directions to or information about interior spaces and facilities to the visual-character requirements of Section 703.5. That does not automatically make every directional sign a tactile/braille sign.
Common federal exceptions
Section 216.1 does not require building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, company names/logos or temporary signs used for seven days or less to comply with Section 216. Other listed facility-specific exceptions may apply.
Pictograms identifying permanent rooms
When a pictogram designates a permanent interior room or space, Section 216.2 requires the pictogram to comply with Section 703.6 and to have text descriptors complying with the tactile and visual provisions. Under Section 703.6, the pictogram field is at least 6 inches high, characters and braille stay out of it, and the text descriptor sits directly below it. The pictogram field, descriptor and braille are separate production zones.
Primary reference: 2010 ADA Standards for Accessible Design, Section 216. This page is a fabrication aid, not project-specific legal or code approval.